ULC 531

Original price was: $300.00.Current price is: $180.00.

Standard for Smoke Alarms (CAN/ULC S531:2019)

Published by Publication Date Number of Pages
ULC 2019

ULC 531 – Standard for Smoke Alarms (CAN/ULC S531:2019)

These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations in accordance with Installation of Smoke Alarms CAN/ULC-S553; National Building Code of Canada; and National Fire Code of Canada. This standard evaluates single station smoke alarms (e.g. ionization-type photoelectric-type smoke alarm with supplementary heat detection type combination smoke type multi-criteria type) as defined by these requirements is a self-contained fire alarm device that consists of an assembly of electrical components including a smoke sensor / chamber alarm sounding appliance and provision for connection to a power supply source either by splice leads terminals a cord and plug arrangement or containing integral batteries to detect one or more products of combustion. The products of combustion may consist of visible as well as invisible smoke particles gases heat radiant energy and water vapor. Additional functionality such as a supplemental heat detector terminals for connection to a remote audible signaling appliance (device) or accessory and an integral transmitter to energize a remote audible signaling appliance (device) is permitted to be incorporated as part of the smoke alarm assembly. Smoke-alarms not intended for interconnection are defined as single-station type. Multiple station units are single station smoke alarms that are interconnected so that actuation of one results in alarm sounding by all interconnected smoke alarms or smoke alarms that are connected to remote heat detectors or heat alarms (thermostats). These requirements where applicable also cover all remote accessories that are to be connected.This standard does not cover the following smoke detectors of the non-self-contained type that are intended for connection to a household or industrial system control unit. These are included in CAN/ULC-S529 Smoke Detectors for Fire Alarm Systems; mechanically operated single and multiple station fire alarm devices that are specified in ULC-ORD-C539 Single and Multiple Station Heat Alarms; heat detectors [except for the requirements in the Fire Test smoke alarm with heat detection (Heat Detector) Section 65] incorporated as part of a single station smoke alarm assembly whose requirements are covered in the CAN/ULC-S530 Heat Actuated Fire Detectors for Fire Alarm Systems and/or when part of a multi-criteria smoke alarm; an accessory that is provided with a means to transmit alarm signals to a constantly attended remote monitoring location. Any accessory capable of transmitting these types of signals is covered by the requirements in CAN/ULC-S545 Residential Fire Warning System Control Units; a gas and vapor detector or sensor incorporated as a part of a smoke alarm assembly and covered by CSA 6.19-01 (R2006) Standard for Carbon Monoxide Alarming Devices except when part of a multi-criteria smoke alarm.

Product Details

Edition:
4
Published:
05/17/2019
Note:
This product is unavailable in Russia Ukraine Belarus
  • ULC 531

    ULC 531

    Original price was: $250.00.Current price is: $150.00. Add to cart